HZ-3510 10A Ground Down Lead Underline Konduzzjoni Tester
10A Ground Down Lead Underline Konduzzjoni Tester
I. L-użu u l-karatteristiċi tal-istrument
The reliable and effective connection between the grounding down conductor of the power equipment and the ground network is the fundamental guarantee for the safe operation of the equipment. The grounding down conductor is the connection part of the power equipment and the grounding grid. During the long-term operation of the power equipment, the connection may be affected by moisture and other factors, and the connection point may be rusted or even broken. The resistance of the grounding grid connection point is increased, which cannot meet the requirements of the electric power regulations, so that there are hidden dangers in the operation of the equipment, and in serious cases, the equipment will lose ground. Therefore, in the "Twenty-Five Key Requirements to Prevent Major Accidents in Electric Power Production", it is clearly stated that the conduction test of the down conductor of the grounding device should be carried out once a year.
It-tester tal-kontinwità tal-ert HZ-3510 huwa tester portabbli bi grad għoli ta 'awtomazzjoni żviluppat mill-kumpanija tagħna. Jintuża biex titkejjel ir-reżistenza tal-kontinwità bejn il-kondutturi ta 'l-art ta' diversi tagħmir ta 'enerġija fis-substation. L-istrument huwa kkontrollat minn mikrokompjuter b'ċippa waħda ta '-prestazzjoni għolja, li jista' jirrealizza l-proċess tat-test intelliġenti. Għandu l-vantaġġi ta 'daqs żgħir, ġarr konvenjenti, tħaddim sempliċi, preċiżjoni għolja, veloċità tat-test mgħaġġla, ttestjar mill-ġdid tajjeb, u qari intuwittiv. Huwa strument speċjali ideali li jissodisfa r-rekwiżiti tar-regolamenti.
II. Indikaturi tekniċi ewlenin
Punt Indikaturi u parametri tekniċi Rimarki
Kurrent tat-test 1A, 3A, 5A, 10A
Measuring range 0.8mΩ-0.8Ω (10A)
1mΩ-2Ω (5A)
5mΩ-3Ω (3A)
10mΩ-10Ω (1A)
Minimum resolution 0.1μΩ
Accuracy ±(0.5 percent plus 2 words)
Display LCD display, display reżistenza ċifri effettivi huma 4 ċifri
Ħażna tad-dejta 1000 grupp
Ambjent tax-xogħol Temperatura ambjentali: 0 grad -40 grad Umdità relattiva:<90%rh, no="">90%rh,>
Power supply Built-in lithium battery AC 220V±10V, 50Hz±1 Hz Fuse 2A
Konsum massimu ta 'enerġija 100W
Dimensjonijiet: tul 300mmwidth 240mmheight 140mm
Strument tal-piż: 3.8Kg Kaxxa tal-wajer: 8.5Kg
III. karatteristiċi funzjonali
1. Il-magna kollha hija kkontrollata minn mikrokompjuter ta '-veloċità waħda-ċippa waħda, bi grad għoli ta' awtomazzjoni u tħaddim faċli.
2. L-istrument jadotta teknoloġija ġdida tal-provvista tal-enerġija tal-marka-, b'ħafna gerijiet kurrenti u firxa wiesgħa ta 'kejl.
3. Teknoloġija ta 'ġestjoni tal-enerġija intelliġenti, l-istrument dejjem jaħdem fl-istat tal-enerġija minima, inaqqas b'mod effettiv it-tisħin intern tal-istrument u jiffranka l-enerġija.
4. 320X240 dot matrix ultra-pixel żgħir 65K LCD kulur veru, wiri ċar taħt dawl qawwi
5. L-istrument għandu l-ħżin tal-qawwa-down tiegħu stess, li jista 'jaħżen 1000 sett ta' data tat-test, li jistgħu jiġu kkonsultati fi kwalunkwe ħin
6. L-istrument jiġi b'batterija tal-litju, mibnija-fil-ċarġer, disinn integrat, faċli biex topera



It-tags Popolari: HZ-3510 10A Ground Down Lead Underline Conduction Tester, Ċina, fornituri, manifatturi, prezz, għall-bejgħ, Ground Continuity Tester, 10a Grounding Lead Conduction Test Apparat, Earth Continuity Test Equipment, ground lead underline konduzzjoni tester, Ground Down Lead Continuity Tester, HZ-3510